EC-105HTP,MTP,MTHP, High and low temperature constant temperature bath (1000L)
Project |
Type |
||||
Series |
HT |
MT |
MTH |
||
function |
Temperature occurs in a way |
Dry wet bulb method |
|||
Temperature range |
-20 ~ + 100 ℃ |
-40 ~ + 100 ℃ |
-40 ~ + 150 ℃ |
||
Range of temperature |
Below the + 100℃ |
± 0.3 ℃ |
|||
+Above the 101℃ |
― |
± 0.5 ℃ |
|||
Temperature distribution |
Below the + 100℃ |
± 1.0 ℃ |
|||
Above the + 101℃ |
― |
± 2.0 ℃ |
|||
The temperature drops the time |
+20 ~ -20 ℃ Within 60 minutes |
+20 ~ -40 ℃ Within 9 0 minutes |
+20 ~ -40 ℃ Within 9 0 minutes |
||
Temperature rise time |
-20 ~ + 100 ℃ Within 45 minutes |
-40 ~ + 100 ℃ Within 50 minutes |
-40 ~ + 150 ℃ Within 75 minutes |
||
The internal volume of the uterus was tested |
1000L |
||||
Test room inch method (width, depth and height) |
1000mm × 1000mm × 1000mm |
||||
Product inch method (width, depth and height) |
1400mm × 1370mm × 1795mm |
||||
Make the material |
External outfit |
Test room control panel machine room |
Cold steel plate, cold steel plate beige (Color table 2.5Y8 / 2) |
||
Inside |
Stainless steel plate (SUS304,2B polished) |
||||
Broken heat material |
Test room |
Hard synthetic resin |
|||
― |
glass wool |
||||
door |
Hard synthetic resin foam cotton, glass cotton |
Project |
Type |
||||
Series |
HT |
MT |
MTH |
||
Cooling dehumidifying device |
Cooling-down method |
Mechanical section shrinkage mode |
|||
Cooling medium |
R404A |
||||
compressor |
Output (number of units) |
0.75kW (1) |
1.5kW (1) |
||
Cooling and dehumidifier |
Multi-channel mixed heat sink type |
||||
The condenser |
Multi-channel mixed radiator plate type (air cooling type) |
||||
Calorifier |
Form |
Nickel-chromium heat-resistant alloy heater |
|||
Volume |
3.5kW |
||||
Blower |
Form |
Multi-channel mixed radiator plate type (air cooling type) |
|||
Motor capacity |
40W |
||||
Controller |
The temperature is set |
-22.0 ~ + 102.0 ℃ |
-42.0 ~ + 102.0 ℃ |
-42.0 ~ + 152.0 ℃ |
|
Humidity is set |
0 ~ 98%RH (But the temperature of the wet and dry bulb is 10-85 ℃ ) |
||||
Time setting Fanny |
0 ~ 999 Time 59 minutes (formula) 0 ~ 20000 Time 59 minutes (formula formula) |
||||
Set decomposition energy |
Temperature 0.1℃, humidity 1% RH for 1 min |
||||
Indicate accuracy |
Temperature ± 0.8℃ (tp.), humidity ± 1% RH (tp.), time ± 100 PPM |
||||
Vacation type |
Value or program |
||||
Stage number |
20-stage / 1 program |
||||
The number of procedures |
The maximum number of incoming force (RAM) programs is 32 programs The maximum number of internal ROM programs is 13 programs |
||||
Round-trip number |
98 times maximum or unlimited |
||||
Number of round-trip repeats |
Maximum 3 times |
||||
Displace the end |
Pt 100Ω(at 0 ℃), gradeB(JIS C 1604-1997) |
||||
Control action |
When splitting the PID action |
||||
Endovirus function |
Early delivery function, standby function, setting value maintenance function, power outage protection function, Power action selection function, maintenance function, transportation round-trip function, Time delivery function, time signal output function, overrising and overcooling prevention function, Abnormal representation function, external alarm output function, setting paradigm representation function, Transport type selection function, the calculation time represents the function, the slot lamp lamp function |
Project |
Type |
||||||
Series |
HT |
MT |
MTH |
||||
Control panel |
Equipment machine |
LCD operating panel (type contact panel), Represents lamp (power, transport, abnormal), test power supply terminal, external alarm terminal, Time signal output terminal, power cord connector |
|||||
Protective device |
Refrigerating cycle |
Overload protection device, high blocking device |
|||||
Calorifier |
Temperature over-rise protection device, temperature fuse |
||||||
Blower |
Overload protection device |
||||||
Control panel |
Leakage breaker for power supply, fuse (for heater, humidifier), Fuse (for operating loop), temperature rise protection device (for testing), Temperature rise overcooling prevention device (test material, in microcomputer) |
||||||
Offproducts (sets) |
House receiving (4), house board (2), operation instructions (1) |
||||||
Equipment products |
Adventitia |
|
|||||
Cable hole |
|
||||||
The trough inside the lamp |
|
||||||
Wheel |
|
||||||
Horizontal adjustment |
|
||||||
Electrovirus characteristics |
Source * |
AC three-phase 380V 50Hz |
|||||
Maximum load current |
13A |
15A |
|||||
Capacity of the leakage breaker for the power supply |
25 A |
||||||
Sensory current 30mA |
|||||||
Power distribution thickness |
8mm2 |
14mm2 |
|||||
Rubber insulation hose |
|||||||
Coarseness of grounding wire |
3.5mm2 |
5.5mm2 |
|||||
Tubing |
drain-pipe * |
PT1/2 |
|||||
Product weight |
470kg |
540kg |