The Relationship Between the Altitude of the Standard Atmosphere and Air Temperature and Pressure

The Relationship Between the Altitude of the Standard Atmosphere and Air Temperature and Pressure

The standard atmosphere referred to here refers to the "1964, ICAO Standard atmosphere" adopted by the International Civil Aviation Organization. Below an altitude of 32 km, it is the same as "1976, U.S. standard atmosphere". Changes in air temperature near the surface (below 32 km) are:

Ground: The air temperature is 15.0℃, the air pressure P=1013.25mb= 0.101325MPa

Temperature change rate from ground to elevation 11 km: -6.5 ℃/ km

On the 11km interface:

The air temperature is -56.5 ℃ and the air pressure P=226.32mb

Temperature change rate at elevations of 11-20 km: 0.0℃/ km

Temperature change rate at altitude 20-32 km: +1.0/ km

The following table lists the temperature and pressure values of the standard atmosphere at different altitudes. In the table, "gpm" is the altitude meter, and its negative sign represents the altitude

Gpm

Temperature℃

Atmospheric pressure(mb)

Gpm

Temperature℃

Atmospheric pressure(mb)

Gpm

Temperature℃

Atmospheric pressure(mb)

-400

17.6

1062.2

4800

-16.2

554.8

10000

-50.0

264.4

-200

16.3

1037.5

5000

-17.5

540.2

10200

-51.3

256.4

0

15.0

1013.3

5200

-18.8

525.9

10400

-52.6

248.6

200

13.7

989.5

5400

-20.1

511.9

10600

-53.9

241.0

400

12.4

966.1

5600

-21.4

498.3

10800

-55.2

233.6

600

11.1

943.2

5800

-22.7

484.9

11000

-56.5

226.3

800

9.8

920.8

6000

-24.0

471.8

11500

-56.5

209.2

1000

8.5

898.7

6200

-25.3

459.0

12000

-56.5

193.3

1200

7.2

877.2

6400

-26.6

446.5

12500

-56.5

178.7

1400

5.9

856.0

6600

-27.9

434.3

13000

-56.5

165.1

1600

4.6

835.2

6800

-29.2

422.3

13500

-56.5

152.6

1800

3.3

814.9

7000

-30.5

410.6

14000

-56.5

141.0

2000

2.0

795.0

7200

-31.8

399.2

14500

-56.5

130.3

2200

0.7

775.4

7400

-33.1

388.0

15000

-56.5

120.5

2400

-0.6

756.3

7600

-34.4

377.1

15500

-56.5

111.3

2600

-1.9

737.5

7800

-35.7

366.4

16000

-56.5

102.9

2800

-3.2

719.1

8000

-37.0

356.0

17000

-56.5

87.9

3000

-4.5

701.1

8200

-38.3

345.8

18000

-56.5

75.0

3200

-5.8

683.4

8400

-39.6

335.9

19000

-56.5

64.1

3400

-7.1

666.2

8600

-40.9

326.2

20000

-56.5

54.7

3600

-8.4

649.2

8800

-42.2

316.7

22000

-54.5

40.0

3800

-9.7

632.6

9000

-43.5

307.4

24000

-52.5

29.3

4000

-11.0

616.4

9200

-44.8

298.4

26000

-50.5

21.5

4200

-12.3

600.5

9400

-46.1

289.6

28000

-48.5

15.9

4400

-13.6

584.9

9600

-47.4

281.0

30000

-46.5

11.7

4600

-14.9

569.7

9800

-48.7

272.6

32000

-44.5

8.7

Unit conversion relation

1mbar=100Pa=0.1KPa=0.0001 Mpa

1ft=0.3048m=304.8mm

55000ft*0.3048=16764m

Lab Companion focused on the production of reliability environmental test equipment for 19 years, successfully helped 18,000 enterprises to test the reliability and environmental performance of products and materials.

The main products are: high temperature test chamber, high and low temperature and humidity test chamber, walk-in environmental test chamber, rapid temperature cycling test chamber, thermal shock test chamber, high and low temperature low pressure test chamber, vibration of the comprehensive chamber and other test equipment manufacturing solutions to help enterprises R & D bigger and stronger!